Menü überspringen

IBV 100 Series

Request

Documentation

undefinedProduct Information

Specifications

IBV 101
IBV 102

Input

1 VPP

Electrical connection

M23 flange socket (female) 12-pin

Cable length

≤ 60 m for UP > 4.9 V

≤ 30 m at IEncoder ≤ 120 mA

Interpolation1)

IBV 101: 5-fold, 10-fold

IBV 102: 20-fold, 25-fold, 50-fold, 100-fold

Input frequency1) for interpolation

Nominal values2)

IBV 101

5-fold

200 kHz

200 kHz

133 kHz

100 kHz

80 kHz

50 kHz

25 kHz

10-fold

200 kHz

100 kHz

66 kHz

50 kHz

40 kHz

25 kHz

12.5 kHz

IBV 102

20-fold

100 kHz

50 kHz

33 kHz

25 kHz

20 kHz

12.5 kHz

6.25 kHz

25-fold

80 kHz

40 kHz

26 kHz

20 kHz

16 kHz

10 kHz

5 kHz

50-fold

40 kHz

20 kHz

13 kHz

10 kHz

8 kHz

5 kHz

2.5 kHz

100-fold

20 kHz

10 kHz

6.6 kHz

5 kHz

4 kHz

2.5 kHz

1.25 kHz

Output1)

TTL (clocked)

Electrical connection

M23 flange socket (male) 12-pin

Cable length

≤ 25 m

≤ 50 m

≤ 75 m

(Uas ≤ 50 m)

≤ 100 m (Uas ≤ 50 m)

Edge separation a

≥ 0.100 µs

≥ 0.220 µs

≥ 0.345 µs

≥ 0.465 µs

≥ 0.585 µs

≥ 0.950 µs

≥ 1.925 µs

Reference mark signal1)

Pulse width 90° elec. or 270° elec.

Fault indication1)

through fault detection signal Uas or, in addition, Ua1/Ua2 high impedance

Power supply

5 V ± 5 %

Current consumption3)

IBV 101: ≤ 120 mA

IBV 102: ≤ 130 mA

Operating temperature

Storage temperature

0 °C to 70 °C

–30 °C to 80 °C

Vibration 50 to 2 000 Hz

Shock 11 ms

≤ 100 m/s2

≤ 300 m/s2

Degree of protection

IP 65

Weight

Approx. 0.3 kg

Bold: This version is the factory default setting, please select when ordering

1) Adjustable

2) The actual input frequency can be up to 5% lower. Exceeding this limit results in failure

3) Not including output load (80 mA with recommended input circuitry) or the current consumption of the encoder
(see the corresponding encoder brochure)